Back to Top
  • +44 (0) 161 633 3933
  • |
  • +44 (0) 161 633 4113

Pressure Reducing Stations | Two Stage Gas Reducing Station

FeaturesHigh Flow Engine Start Reducing Station

  • Regulator isolators and bypass facility allows supply of air during maintenance.

  • Non-isolatable relief valve protects downstream system and pipe work.

  • Upstream and downstream pressure gauge isolators with vent for gauge blow-down.

  • 50 micron inlet filter protects regulator and downstream equipment.

  • Cartridge principle allows full maintenance of all valves with block in situ.



Specifications

  • Applications: Air supply to all functions or gas supply.

  • Design Pressure: 280 bar at 40 C.

  • Temperature Range: -25 to 120 C.

  • Max. Flow Rates: To Customer Specifications

  • Shock tested to 80g for 5 milliseconds in half sine wave. Any orientation.

  • Vibration tested to MIL-STD-167-1, Type 1 (available on request).


Model No. Weight kg
(Est'd)
Inlet Pipe Size Outlet Pipe Size Block Dimensions
Length, L Width, W Height, H
RSA 45 1/4" NPS 1/2" NPS 345mm 317mm 172mm