Features 
-
Regulator isolators and bypass facility allows supply
of air during maintenance.
-
Non-isolatable relief valve protections of downstream
system and pipe work.
-
Upstream
and downstream pressure gauge isolators with vent for
gauge blow-down.
-
50 micron
inlet filter protects regulator and downstream equipment.
-
Cartridge principle allows full maintenance of all
valves with block in situ.
-
Twin
Regulators give back-up in the event of failure of one
regulator.
Specifications
-
Applications: Breathing air supply to hyperbaric
chambers.
-
Design Pressure: 4000 psig at 100° F.
-
Temperature Range: -4 to 240° F.
-
Max. Flow Rates: To Customer Specifications
-
Shock tested to 80g for 5 milliseconds in
half sine wave. Any orientation.

| Model No. |
Weight lbs
(Estimated) |
Inlet Pipe Size |
Outlet Pipe Size |
Block Dimensions |
| Length, L |
Width, W |
Height, H |
| RSA 01 |
136 |
3" |
3 ½" |
12.6" |
6.5" |
5.5" |
|
|
|
|